Philips HeartStart HS1 OnSite Defibrillator

Simple design allows defibrillator to be used by those with no medical or defibrillator training
  • Unit detects a shockable heart rhythm in a heart attack victim and will not allow a shock to be given if it is not required
  • Daily, weekly, and monthly self-tests ensure that the defibrillator is always ready to use
  • Guided audio instructions provide clear voice prompts to guide user through AED and CPR procedures for both adults and children
View full product information

Philips HeartStart HS1 OnSite Defibrillator

Highly Flammable 3 Easy Peel Warning Diamond
£1,350.00 Incl. VAT: £1,620.00

Style No.

305ZDA120
Supplied in : Single
Request a Quote Price Match

Details

Philips HeartStart HS1 OnSite Defibrillator

  • Calm, clear voice instructions are tailored to the responder’s actions, providing guidance during the resuscitation of a sudden cardiac arrest victim
  • Clear, graphics-based visual instructions support vocal instructions, ensuring that minimum reading is required when time is of the essence
  • Smart biphasic therapy safely delivers maximum shock strength, using a unique combination of high current to maximise effectiveness and lower energy dose to minimise side effects
  • Studies have shown that CPR is even more vital to a victim’s survival and rapidly delivering a shock after chest compressions is critical
  • The AED’s Quick Shock feature reduces the time between hands-off and shock delivery
  • The unit is easy to operate and simply turns on with an easy-to-use pull handle
  • Provided with pre-connected SMART pads, which are also tested for readiness
  • The pads sense when they have been applied to the patient’s skin, helping the HeartStart know at what stage of resuscitation the user is at
  • Philips Heartstart Smart Pads Cartridge - Adult and Philips Heartstart Smart Pads Cartridge - Infant available
  • Ensure your defibrillator has optimal battery life by having a replacement Philips Battery Pack in stock
  • Summary of the key features
  • Heart-rhythm assessment provided by SMART Analysis technology
  • SMART Biphasic energy delivery
  • Can be used on children (using the paediatric pads available separately)
  • Clear voice instructions including CPR coaching
  • Quick Shock ability enables the unit to deliver shock therapy rapidly after CPR
  • SMART electrode pads detect when they have been removed from the cartridge
  • Daily self-tests check electrical the components, subsystems and battery
  • Ready light shows when the defibrillator is ready for use
  • IPx5 protection rating (please see our AED buying guide for what this means)
  • Technical Specifications
  • Battery: 9 volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cells
  • Capacity: Minimum 200 shocks or 4 hours of operating time (EN60601-2-4:2003)
  • Install-by Date: Battery is labeled with an install-by date of at least five years from date of manufacture
  • Standby Life: Four years typical when battery is installed by the install-by date. (Will power the AED in standby state within the specified Standby Temperature range, assuming one battery insertion test and no defibrillation uses)
  • Waveform: SMART Truncated exponential biphasic. Waveform parameters adjusted as a function of patient impedance
  • Defibrillation peak current - Adult: 32 A (150 J nominal) into a 50 ohm load
  • Defibrillation peak current - Pediatric: 19 A (50 J nominal) into a 50 ohm load (using optional infant/child SMART Pads Cartridge)
  • Quick Shock: Able to deliver a shock after the end of a CPR interval, typically in eight seconds
  • Shock-to-Shock Cycle Time: Typically less than 20 seconds between shocks in a series
  • Voice Instructions: Detailed voice messages guide responder through use of the defibrillator
  • CPR Guidance: Instructions for adult and infant/child CPR available at user selection
  • Shock Delivery: Via adhesive pads placed on patient's bare skin as illustrated on pads
  • Controls: Green SMART Pads cartridge handle, green On/Off button, blue i-button, orange Shock button
  • Indicators: Ready light, blue i-button, caution light
  • Standby Temperature: 0 - 43 °C (32 - 109 °F)
  • Operating Humidity: 0 to 95 % relative humidity (non-condensing)
  • Standby Humidity: 0 to 75 % relative humidity (non-condensing)
  • Standby Altitude: 48 hours from 0 to 8,500 ft and <48 hours from 8,500 to 15,000 ft
  • EMI (Radiated/Immunity): Meets EN55011 Group 1 Level B Class B and EN61000-4-3
  • Operating Temperature: 0 - 50 °C (32 - 122 °F)
  • Operating Altitude: 0 to 4,500 m (0 to 15,000 ft)
  • Shock/Drop Abuse Tolerance: Withstands 1 meter drop to any edge, corner, or surface
  • Vibration: Meets EN1789 random and swept sine, road ambulance specification in operating and standby states
  • Automated and User-activated Self-tests: Daily Automatic Self-tests
  • Tests internal circuitry, waveform delivery system, pads cartridge, and battery capacity
  • Pads Integrity Test: Specifically tests readiness-for-use of pads (gel moisture)
  • Battery Insertion Test: Upon battery insertion, extensive automatic self-tests and user-interactive tests check device readiness
  • Status Indicator: Blinking green "Ready" light indicates ready for use. Audible "chirp" indicates need for maintenance
  • Data Recording and Transmission: Wireless transmission of event data to a PC or Palm PDA, using the IrDA protocol
  • Data Stored: First 15 minutes of ECG and the entire incident's events and analysis decisions

Specifications

Battery Included?
Yes
Brand
Philips
Classes
IP 20
Clothing Size
Adult/child
Colour(s)
Blue
Defibrillator Type
Semi Automatic
Kit Contains
Pre-Installed battery
Pre-Installed SMART Pads Cartridge
Quick Set-Up Guide
Maintenance Booklet
Quick Reference Guide
Owners Manual
Slim Carrying Case
Material
Plastic
Size (H x W x L)
11 x 23 x 24 cm
Supplied in
Single
Training Material
No
Type
Semi-Automatic
Weight
1.7 kg

Documentation

Product Guides & Training Tools

Technical Information


  • Philips HeartStart HS1 Defibrillator
    > Download

£5.95 delivery charge for all orders*

To learn more about dispatch, delivery and returns, please visit our page or call us on 0800 316 9700.

*Orders to non-mainland UK locations and non-stock items (such as bulky, heavy or hazardous goods) may be subject to delivery charges. In the unlikely event that your order incurs additional charges, you will be contacted by our Customer Service Team at the point your order is being processed.